Skip to main content

India Mark II Access Door Replacement

What you need

  1. India Mark II Access Door Replacement, Access Door: step 1, image 1 of 2 India Mark II Access Door Replacement, Access Door: step 1, image 2 of 2
    • Before performing any repairs, perform a water test on the pump by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.

    • Remove the hex head bolt from the top of the access door on the pump head.

    • On reassembly, this bolt should be hand-tight.

  2. India Mark II Access Door Replacement: step 2, image 1 of 3 India Mark II Access Door Replacement: step 2, image 2 of 3 India Mark II Access Door Replacement: step 2, image 3 of 3
    • Pull the access door straight up off the pump head.

    • Store the access door in a sanitary place to prevent contamination.

  3. India Mark II Access Door Replacement: step 3, image 1 of 2 India Mark II Access Door Replacement: step 3, image 2 of 2
    • The access door has a tongue that fits into the base of the pump head.

    • The access door makes a convenient tray to hold nuts and bolts during the disassembly.

Conclusion

To reassemble your device, follow these instructions in reverse order.