Disconnect one wire from the element carefully to avoid sharp edges.

Use the multimeter on ohms or continuity and expect about 43 ohms for a healthy heating element.

Move one lead to the purple wire side and measure about 21 ohms to each half of the element coils.

Replace the heating element if readings show open line or are significantly off from expected values.